Compatible Drager Spirolog Flow Sensor, SpiroQuant A+ Mass flow measurement. For use with Draeger Evita series, Primus and Cicero systems. This flow sensor is used for measuring volume flows in anesthesia and ventilation applications. Sold in case of 5.

Specifications:
Accurate: Temperature compensated, low pressure drop.

Reliable: Fast response time, long durability.

Measuring principle: Constant temperature hot wire anemometry

Application: Designed for flow module SpiroQuant MAX (compatible with Dräger Spirolog sensor)

Flow range: 0 to 160 SLPM

Accuracy: ± 5 % reading with flow module SpiroQuant MAX (± 8 % used in Dräger ventilators)

Added resistance: <92.5 mba="" br="">
Pressure range: ± 100 mbar

Connection: Gold plated 4 pin (compatible with Dräger Spirolog sensor)

Operating temperature: +15 to +40°C

Storage temperature: - 20 to +40°C

Lifetime: Applicable as long as a sensor calibration is successful

Material: MABS

Disinfection: Single patient use recommended / disinfection in 70% ethanol solution without mechanical influence of hot-wires inside of sensor possible.

OEM

  • Draeger: 843735
  • Draeger: 8403735
$$112.50 USD WholeSale

Compatible Drager Flow Sensor 843735

Compatible Drager Spirolog Flow Sensor, SpiroQuant A+ Mass flow measurement. For use with Draeger Evita series, Primus and Cicero systems. This flow sensor is used for measuring volume flows in anesthesia and ventilation applications. Sold in case of 5.

Specifications:
Accurate: Temperature compensated, low pressure drop.

Reliable: Fast response time, long durability.

Measuring principle: Constant temperature hot wire anemometry

Application: Designed for flow module SpiroQuant MAX (compatible with Dräger Spirolog sensor)

Flow range: 0 to 160 SLPM

Accuracy: ± 5 % reading with flow module SpiroQuant MAX (± 8 % used in Dräger ventilators)

Added resistance: <92.5 mba="" br="">
Pressure range: ± 100 mbar

Connection: Gold plated 4 pin (compatible with Dräger Spirolog sensor)

Operating temperature: +15 to +40°C

Storage temperature: - 20 to +40°C

Lifetime: Applicable as long as a sensor calibration is successful

Material: MABS

Disinfection: Single patient use recommended / disinfection in 70% ethanol solution without mechanical influence of hot-wires inside of sensor possible.

OEM

  • Draeger: 843735
  • Draeger: 8403735
BACK ORDER